Test Code MISCLM - LAB2608 Magnesium, 24 Hour, Urine
Additional Codes
SQ: MISCLM
MAY: MAGU
Useful For
Assessing the cause of abnormal serum magnesium concentrations using a 24-hour urine collection
Determining whether nutritional magnesium loads are adequate
Calculating urinary calcium oxalate and calcium phosphate supersaturation and assessing kidney stone risk
Special Instructions
Method Name
Colorimetric Endpoint Assay
Reporting Name
Magnesium, 24 HR, USpecimen Type
UrineNecessary Information
Specimen volume in milliliters and duration are required.
Specimen Required
Supplies: Sarstedt 5 mL Aliquot Tube (T914)
Collection Container/Tube: 24-hour graduated urine container with no metal cap or glued insert
Submission Container/Tube: Plastic, 5 mL tube or a clean, plastic urine container with no metal cap or glued insert
Specimen Volume: 4 mL
Collection Instructions:
1. Collect urine for 24 hours.
2. Refrigerate specimen within 4 hours of completion of 24-hour collection.
Additional Information: See Urine Preservatives-Collection and Transportation for 24-Hour Urine Specimens for multiple collections.
Specimen Minimum Volume
1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 14 days | |
Frozen | 30 days | ||
Ambient | 72 hours |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability. |
Reference Values
51-269 mg/24 hours
Reference values have not been established for patients <18 years and >83 years of age.
Method Description
In alkaline solution, magnesium forms a purple complex with xylidyl blue, diazonium salt. The magnesium concentration is measured photometrically via the decrease in xylidyl blue absorbance.(Package insert: Roche MG2 kit. Roche Diagnostics;Â V8.0 01/2020)
Performing Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
83735
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
MAGU | Magnesium, 24 HR, U | 24447-5 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
MG24 | Magnesium, 24 HR, U | 24447-5 |
TM115 | Collection Duration | 13362-9 |
VL111 | Urine Volume | 3167-4 |
Forms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.
Secondary ID
610768Day(s) Performed
Monday through Sunday