Test Code LAB4638 PAP Smear, Liquid-Based, SurePath
Additional Codes
Test manually ordered in Powerpath
Collection
Patient Preparation:
- Broom-Type Detachable Head Device
- Insert Rover Cervex-Brush into the endocervical canal.
- Rotate brush 5 times in a clockwise direction.
- Snap the detachable head of the device off into the BD SurePath vial. Be careful not to touch the head of the device. Place the cap on the vial and tighten.
- Brush/Plastic Spatula Detachable Head Device:
- Insert the contoured end of the plastic spatula and rotate 360° around the entire exocervix.
- Insert the Cytobrush into the endocervix until only the bottom-most bristles are exposed at the os.
- Slowly rotate 1/4 to ½ turn in one direction. Do not over rotate brush.
- Snap the device handle at the red scoring line and drop the detachable head of the device into the BD SurePath vial.
- Place the cap on the vial and tighten.
Specimen Type:
- Cervical Pap collection in a SurePath Pap Collection Vial
Minimum Volume:
- Entire PAP collection
Reasons for Rejection:
- Specimen does not meet collection, storage, or transport requirements.
Stability
Ambient: 30 days
Refrigerated: 6 months
Frozen: Unacceptable
Reference Ranges
NIL (Negative for Intraepithelial Lesions)
Methodology
- BD FocalPoint GS Imaging System
- Manual microscopic review.
Performing Laboratory
UnityPoint Health Trinity Rock Island, IL
Days Performed:
- Monday-Friday
Analytical Time:
- 48 hours.
CPT Codes
-
88175 (SurePath FocalPoint Imaged Guided Screening)
88142 (if appropriate, manual Cytotechnologist screening)
88141 (if requires Pathologist review)