Test Code LAB3921 HPV High Risk Screen, TMA, Pap
Additional Codes
Sunquest: HPVHRO
Collection
Patient Preparation:
Broom-Type Detachable Head Device
-
Insert Rover Cervex-Brush into the endocervical canal.
-
Rotate brush 5 times in a clockwise direction.
-
Snap the detachable head of the device off into the BD SurePath vial. Be careful not to touch the head of the device. Place the cap on the vial and tighten.
Brush/Plastic Spatula Detachable Head Device:
-
Insert the contoured end of the plastic spatula and rotate 360° around the entire exocervix.
-
Insert the Cytobrush into the endocervix until only the bottom-most bristles are exposed at the os.
-
Slowly rotate 1/4 to ½ turn in one direction. Do not over rotate brush.
-
Snap the device handle at the red scoring line and drop the detachable head of the device into the BD SurePath vial.
-
Place the cap on the vial and tighten.
Specimen Type:
Pap collection in a SurePath Pap Collection Vial
*Specimen will be transferred from SurePath Pap Collection Vial to Aptima Transfer Tube in lab before testing.
Minimum Volume:
1mL
Reasons for Rejection:
Collection in a non-sterile container or does not meet collection, storage, or transport requirements.
Stability
Ambient: 7 days
Refrigerated: 7 days
Frozen: Unacceptable
Reference Ranges
Negative
Methodology
Transcription Mediated Amplification (TMA
Dual Kinetic Assay (DKA)
Hybridization Protection Assay (HPA)
Performing Laboratory
UnityPoint Health Trinity Rock Island, IL
Days Performed:
Sunday-Saturday
Analytical Time:
24-36 hours.
CPT Codes
High Risk HPV-87624