Test Code LAB311 Antithrombin III Activity
Additional Codes
SQ: AT3
Collection
LIGHT BLUE (CITRATE)
Promptly after collection, spin down and place 1 mL of platelet poor plasma in plastic vial.
- Platelet poor plasma:
-
Centrifuge, transfer top 3/4 of plasma into a plastic vial, and centrifuge plasma again.
-
Aliquot top 3/4 plasma into a separate plastic vial, using this for testing. Discard the vial with the remaining plasma.
-
Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.
-
Glass vial is not acceptable. Freeze specimen immediately .
Stability
Refrigerated: Not acceptable
Frozen stability: 30 days
Ambient stability: 8 hours
Methodology
Chromogenic Assay
Performing Laboratory
Iowa Methodist Medical Center
Pathology Laboratory
Lab section: Core Laboratory
CPT Codes
85300
ANALYTICAL TIME
TESTING PERFORM TUESDAY AND THURSDAY.