Sign in →

Test Code LAB242 Culture, Fungal, Blood

Important Note

  • Source and volume required on patient label.
  • Identification and susceptibility tests are billed separately from culture.
  • No more than 3 cultures will be accepted per patient per 24-hour period unless authorized by Microbiology Manager, Pathologist, or Director of Laboratory Services. Contact laboratory for collection media.
  • Contact Microbiology department for collection media (309-779-2120).
Infectious

Additional Codes

Sunquest: CBLFUN

Collection

Patient Preparation:

Clean venipuncture site with Chloraprep swab for 15 seconds. Allow to dry for 30 seconds. The site must be dry before performing venipuncture. Disinfect the top of the tube stopper with 70% isopropyl alcohol wipe prior to collection and inoculation. Do not touch the site with any non-sterile object.

Specimen Type:

BD Vacutainer SPS Glass Isolator Tube

Collecting optimal volume significantly increases the recovery rate.

Minimum Volume:

1mL

Reasons for Rejection:

Clotted, improper container, or does not meet collection, storage, or transport requirements.

Stability

Ambient: 24 hours

Refrigerated: 24 hours

Frozen: Unacceptable

Reference Range

Culture Dependent

Performing Laboratory

UnityPoint Health Pathology Laboratory Ankeny, IA

Days Performed:

Set up Sunday-Saturday (Cultures read on day shift only).

Analytical Time:

Smear: 24 hours

Culture: 8 weeks

CPT Codes

Culture- 87105

Smear- 87206

Identification- 87116