Test Code Epic LAB785 Bartonella Antibody Panel, IgG and IgM, Serum
Additional Codes
SQ code BARTM
Mayo code BART
Reporting Name
Bartonella Ab Panel, IgG and IgMSpecimen Type
SerumPerforming Laboratory
Mayo Clinic Laboratories in RochesterUseful For
Diagnosis of Bartonella infection, especially in the context of a cat scratch
Testing Algorithm
For information see Infective Endocarditis: Diagnostic Testing for Identification of Microbiological Etiology.
Specimen Required
Supplies: Sarstedt Aliquot Tube 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions: Centrifuge and aliquot serum into plastic vial.
Specimen Minimum Volume
0.15 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 30 days | |
Frozen | 30 days |
Special Instructions
Reference Values
BARTONELLA HENSELAE
IgG: <1:128
IgM: <1:20
BARTONELLA QUINTANA
IgG: <1:128
IgM: <1:20
Day(s) Performed
Monday through Saturday
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
86611 x 4
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
BART | Bartonella Ab Panel, IgG and IgM | 90251-0 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
15659 | Bart Henselae IgG | In Process |
15660 | Bart Henselae IgM | In Process |
15661 | Bart Quintana IgG | In Process |
15662 | Bart Quintana IgM | In Process |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Method Name
Immunofluorescence Assay (IFA)
Method Description
The Euroimmun indirect immunofluorescence test is a standardized, in vitro assay for the determination of specific antibodies against Bartonella henselae and Bartonella quintana. BIOCHIP Mosaics are coated with B henselae and B quintana infected cells positioned next to each other in one reaction field. Samples are diluted and incubated on the substrate slides. If the reaction is positive, specific antibodies of class IgG and IgM attach to the antigens. In a second step, the attached antibodies are stained with fluorescein-labeled anti-human antibodies and made visible using fluorescence microscopy. Semiquantitative endpoint titers are obtained by testing serial dilutions of positive specimens.(Unpublished Mayo method)
Report Available
Same day/1 to 3 daysForms