Test Code Epic LAB370 Cadmium, 24 Hour, Urine
Additional Codes
SQ code UCD24M
Mayo code CDU
Reporting Name
Cadmium, 24 Hr, USpecimen Type
UrinePerforming Laboratory
Mayo Clinic Laboratories in RochesterUseful For
Detecting exposure to cadmium, a toxic heavy metal, in 24-hour urine specimens
Ordering Guidance
If employees are being monitored in the workplace, OSHA requires that laboratory reports express the cadmium excretion rate per gram of creatinine rather than per 24 hours. Order CDUOE / Cadmium, Occupational Exposure, Random, Urine to accommodate that requirement. Mayo Clinic Laboratories is certified to provide this test.
Necessary Information
24-Hour volume (in milliliters) is required.
Specimen Required
Patient Preparation:
1. For the 48-hour period prior to start of collection, as well as during the collection, patient should not eat seafood.
2. High concentrations of gadolinium and iodine are known to interfere with most metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.
Supplies: Urine Tubes, 10 mL (T068)
Collection Container/Tube: Clean, plastic urine container with no metal cap or glued insert
Submission Container/Tube: Plastic, 10-mL urine tube or clean, plastic aliquot container with no metal cap or glued insert
Specimen Volume: 3 mL
Collection Instructions:
1. Collect urine for 24 hours.
2. Refrigerate specimen within 4 hours of completion of 24-hour collection.
3. See Metals Analysis Specimen Collection and Transport for complete instructions.
Additional Information: See Urine Preservatives-Collection and Transportation for 24-Hour Urine Specimens for multiple collections.
Specimen Minimum Volume
1.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 28 days | |
Ambient | 28 days | ||
Frozen | 28 days |
Special Instructions
Reference Values
0-17 years: Not established
≥18 years: <0.7 mcg/24 h
Day(s) Performed
Monday through Friday
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
82300
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
CDU | Cadmium, 24 Hr, U | 5612-7 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
31106 | Cadmium, 24 Hr, U | 5612-7 |
TIME7 | Collection Duration | 13362-9 |
VL83 | Total Volume | 3167-4 |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Method Name
Triple-Quadrupole Inductively Coupled Plasma Mass Spectrometry (ICP-MS/MS)
Method Description
The metal of interest is analyzed by triple-quadrupole inductively coupled plasma mass spectrometry.(Unpublished Mayo method)